  • Red light source calibration for ASEAN ten countries

    Red light source calibration for ASEAN ten countries

    On May 7, 2026, the ASEAN Secretariat announced the operational launch of the 'Industrial Metrology Green Corridor', enabling automated verification of CNAS-issued calibration and verification certificates across customs systems of all ten ASEAN member states. This development significantly impacts. The implementation of mandatory Minimum Energy Performance Standards (MEPS) for lighting appliances is one of the key priorities for ASEAN countries to promote energy efficiency. As stated in the Regional Policy Roadmap for MEPS for Lighting, ASEAN countries aim to implement mandatory MEPS by 2030. Asian Nations (ASEAN) was established on 8 August 1967. The Member States of the Association are Brunei Darussalam, Cambodia, Indonesia, Lao PDR, Malaysia, Myanmar, Philippines, Singapore, Thailand and Viet Nam. The ASEAN Secretariat is based in Jakarta, Indonesia. Market Integration – Trade. The global calibration light sources market size was valued at approximately USD 450 million in 2023 and is projected to reach around USD 720 million by 2032, growing at a compound annual growth rate (CAGR) of 5.

    [PDF Version]
  • Soldering Method for Main Line of Distribution Box

    Soldering Method for Main Line of Distribution Box

    A temperature-controlled soldering iron (25 to 60 watts) is needed for most common wire gauges, allowing for precise heat management. The solder should be rosin-core, which contains flux designed to clean copper oxides during heating, making it ideal for electrical applications. Why Publish? Soldering Multiple Wires for a Distribution Joint: Sometimes it's necessary to split power/signal from a single wire to multiple outputs. Normally I'd prefer to use a terminal/distribution block for something like this, but sometimes that's not feasible, such as when space is. FULLPAK, MicroLeadless, MOSORB, MiniMOSORB, and POWERTAP are trademarks of Semiconductor Components Industries, LLC dba “onsemi” or its affiliates and/or subsidiaries in the United States and/or other countries. Cho−Therm is a registered trademark of Chromerics, Inc. Useful for through-hole components and some SMD soldering Blade – Spreads heat over thin, wide area. ) Changing Tips – Can be done during soldering, but be careful (solder probe. Soldering wires is the process of joining electrical conductors using a melted filler metal to create strong, low-resistance connections.

    [PDF Version]
  • Emergency Power Outage Wiring Method for Distribution Boxes

    Emergency Power Outage Wiring Method for Distribution Boxes

    Check for proper IP/NEMA ratings and material quality. Ensure safe placement: install in dry, accessible areas with good ventilation and at appropriate height (typically ~1. Reliability of these types of systems is critical and good design practices are essential. Classification of Emergency and. Selective coordination is required between breaker “XYZ” and the next downstream overcurrent device in the nonemergency system. Code Change Summary: Revisions were made to the separation requirements for emergency and non-emergency wiring. The general rule in NEC ® 700. The EPO actuator (buton). The EPO wiring diagram is a visual representation of how the emergency power-off circuit is connected and operates.

    [PDF Version]
  • Neutral grounding method for relay protection

    Neutral grounding method for relay protection

    Explore 4 methods of neutral grounding, including solid, resistance, reactance, and Peterson Coil grounding, to enhance safety and system reliability. Neutral grounding connects the neutral point of an electrical system to the earth, providing a secure pathway for fault currents. Neutral grounding method determines fault current magnitude, relay coordination requirements, and transient overvoltage behavior across your entire medium-voltage protection system. Examples of proper applications within various industries will. Next, we describe directional elements suitable to provide ground fault protection in solidly- and low-impedance grounded distribution systems.

    [PDF Version]
  • Cable Tray Funnel Installation Method

    Cable Tray Funnel Installation Method

    Spring knot is used to connect cable tray or trunking to channel. Approved and correct fittings are used. Installed containments are free of damages. Whether you're building a commercial setup or upgrading an industrial plant, proper cable tray installation ensures neat wiring, safe access, and easy maintenance. This guide breaks down the process step by step. In order to install the cable tray supports, first find the required elevation from. The purpose of this article is to define the sequence and methodology for the installation of electrical cable trays, cable trunking, cable raceways and boxes, junction and pull boxes. Our knowledgeable production team works closely with each customer to provide quality solutions based on your schedule and budget.