Checking the optical port signal on a Huawei switch

Use Huawei commands like display transceiver and display interface to monitor optical port signals, RX/TX power, and transceiver status.

Viewing Optical Module Information

To check the optical port signal and transceiver details:

  • All optical ports: Run display transceiver to view information for all optical modules on the switch, including type, connector, wavelength, transfer distance, and vendor details .
  • Specific port: Run display transceiver interface to view details for a single port. Adding the verbose parameter shows receive (RX) and transmit (TX) power, temperature, voltage, and bias current . Example output includes:
  • RX Power (dBm) – current received signal strength
  • TX Power (dBm) – current transmitted signal strength
  • High/Low thresholds for RX/TX power
  • Temperature and voltage of the module

Checking Port Link and Status

  • Use display interface to check link status, port rate, transceiver type, and traffic statistics.
  • display interface brief shows a summary of all ports, including UP/DOWN status .
  • UP indicates a normal link; DOWN may indicate a problem with the transceiver, fiber, or configuration.

Troubleshooting Optical Signal Issues

  1. LOS Alarm (Loss of Signal): Indicates no inbound signal. Check the fiber connection and module compatibility. Use undo shutdown if the port is administratively down .
  2. RX Power too low: May be caused by excessive distance, broken fiber, or faulty module.
  3. RX Power too high: Could result from using a long-distance module on a short link; consider using an optical attenuator.
  4. TX Power too low: Faulty or low-quality transceiver may cause packet loss or port down.
  5. TX Power too high: Excessive signal may damage the receiving end; check module specifications .

Recommended Commands Summary

PurposeCommand
View all transceiversdisplay transceiver
View specific transceiverdisplay transceiver interface
View detailed RX/TX powerdisplay transceiver interface verbose
Check port link and trafficdisplay interface
Summary of all portsdisplay interface brief

By using these commands, you can monitor optical port signals, detect abnormal RX/TX power, and troubleshoot transceiver or fiber issues effectively on Huawei switches .

How to Check SFP Power in Huawei Switch? Is Your Network

If your network feels sluggish or devices mysteriously disconnect, the culprit might be smaller than you think—buried inside your

Huawei S Series Campus Switches Troubleshooting Guide (V100 and

Why Cannot Connected Optical Ports Go Up After Single-Fiber Bidirectional Optical Modules Are Used? How Do I Ensure that the

Optical Module Troubleshooting

Check whether an optical module that is certified for Huawei data center switches is installed on the optical interface.

Troubleshooting S Series Switch Port and Interface Problems

Troubleshooting S Series Switch Port and Interface Problems This document describes how to check the switch interface or port

Checking TX / RX optical power for Huawei Switches and Routers

Checking TX / RX optical power for Huawei Switches and Routers Here is an example on how to query or display optical power of an

Troubleshooting S Series Switch Port and Interface Problems

When connecting two devices, check whether optical modules match optical interfaces, whether optical modules match fiber models,

Checking the Interface Status and Configuration Parameters

Check the status and configuration parameters of the interfaces on the two ends. Ensure that the interfaces run properly and have

Checking the optical attenuation of Huawei switches

Run the display transceiver [interface interface-type interface-number | slot slot-id], to view the information on the optical module

Troubleshooting for Optical Modules on Huawei Switch

Check whether the fiber length between the two ports is within the maximum transmission range of the optical modules on the ports.

Troubleshooting for Optical Modules on Huawei Switch

If the transmit power remains low, replace the optical module or install it in another optical port to check whether it is faulty. If the

How To Check If Interconnected Optical Ports Cannot Go Up?

Run the display device command to check the switch model. Different optical interfaces may support different types of optical

Checking TX / RX optical power for Huawei Switches and Routers

Here is an example on how to query or display optical power of an interface in a Huawei Router. This is tested using NetEngine40E